The EEC-35+ is a new generation eddy current instrument with full-digital, multi-frequency, multi-channel. This intelligent tester is designed for real-time effectively defect detection in metal materials, thickness measurement and sorting materials by metallurgical differences, and weld inspection.
The EEC-35+ is a multi-purpose instrument, which allow you to detect multiple types of defects simultaneously, such as
surface and sub-surface flaws, for faster, easier inspections. It can be used to test conductive materials and measure the coating
thickness. EDDYSUN own the advanced mixing algorithms, providing |
 |
 |
| |
the cleanest, most effective signal mixes. The signals
from two frequencies can be mixed to suppress unwanted signals, improving the signal-to-noise ratio. The audio, visual and
logic output alarms can determined flaw conditions. Real-time C-scan display helps you to differentiate between multiple layers
and determine flaw orientation. |
| |
| Features |
| · |
Dual eddy current frequencies |
| · |
Frequency range from 64Hz to 4MHz |
| · |
4 independently-selectable channel |
| · |
Signal mixing capabilities |
| · |
Adjustable gain from 0dB to 90dB in 0.5dB steps |
| · |
360 degrees phase shift can be varied in steps of 1 degree, the impedance plane can be rotated during modification for ease of operation |
| · |
Colored real-time display of x-y impedance plane and/or strip chart signals. |
| · |
A-scan and C-scan displays |
| · |
Display 3-simultaous x-y signals 2 built-in strip chart signals |
| · |
Delay erase display mode |
| · |
Independent vertical to horizontal display scaling ratio adjustable from 0.1 to 10 |
| · |
Viewing area (Enlarge location area signal) |
| · |
All instrument settings are shown on the display. |
| · |
Digital filters |
| · |
Audio, visual and logic output alarms |
| · |
Fast electronic balancing |
| · |
Special alarm areas adjustable from 1 to 8 |
| · |
Signal phase and amplitude auto measurement functions |
| · |
Alarm area is provided for each display window of impedance plane |
| · |
Adjustable sampling rate. |
| · |
Four connectors are provided for differential, absolute |
| · |
Alarm area size and positioning are independently adjustable and reflection type probes
either inside or outside the gated area |
| · |
Other connects are provided for rotating probe |
| · |
Phase/amplitude alarm area: The amplitude of alarm area is a function versus its phase, so defects in different layer which have the same amplitude level can be distinguished by their phases. |
| · |
Alarm can be set to trigger. |
|
|
 |
 |
 |
|
 |
|